« Previous
Next »
Seminars in Arthroplasty
Volume 22, Issue 4
, Pages 229-233
, December 2011
Ten-Year Follow-Up of Patients Younger Than 50 Years With Modern Ceramic-on-Ceramic Total Hip Arthroplasty
References
- Total hip arthroplasty for primary osteoarthritis in patients fifty-five years of age or older (An analysis of the Finnish arthroplasty registry) . J Bone Joint Surg Am . 2008;90:2160–2170
- Population-based rates of revision of primary total hip arthroplasty: A systematic review . PLoS ONE . 2010;5:e13520
- . Survival of hip replacements (A comparison of a randomized trial and a registry) . Clin Orthop Relat Res . 2000;375:157–167
-
The Swedish total hip replacement register
.
J Bone Joint Surg Am
. 2002;84-A(suppl 2):2–20
- Total hip arthroplasty in patients 50 years and younger . Clin Orthop Relat Res . 2004;418:119–125
- Failed metal-on-metal hip arthroplasties: A spectrum of clinical presentations and operative findings . Clin Orthop Relat Res . 2010;468:2313–2320
- The prevalence of groin pain after metal-on-metal total hip arthroplasty and total hip resurfacing . Clin Orthop Relat Res . 2010;468:2346–2356
- Incidence of groin pain after metal-on-metal hip resurfacing . Clin Orthop Relat Res . 2010;468:392–399
- Third-generation alumina-on-alumina ceramic bearings in cementless total hip arthroplasty . J Bone Joint Surg Am . 2007;89:2676–2683
- Alumina-on-alumina total hip arthroplasty: A concise follow-up, at a minimum of ten years, of a previous report . J Bone Joint Surg Am . 2010;92:1715–1719
-
.
Ten-year results after cementless THA with a sandwich-type alumina ceramic bearing
.
Orthopedics
. 2010;33:796
-
Alumina-on-alumina total hip arthroplasty: A minimum 18.5-year follow-up study
.
J Bone Joint Surg Am 84
. 2002;69–77
- Primary cementless total hip arthroplasty with an alumina ceramic-on-ceramic bearing: Results after a minimum of twenty years of follow-up . J Bone Joint Surg Am . 2010;92:639–644
-
Fractures of ceramic bearings: History and present status
.
Clin Orthop Relat Res
. 2003;417:19–26
- . Ceramic femoral head retrieval data . Clin Orthop Relat Res . 2000;379:22–28
- . Traumatic arthritis of the hip after dislocation and acetabular fractures: Treatment by mold arthroplasty (An end-result study using a new method of result evaluation) . J Bone Joint Surg Am . 1969;51:737–755
- . Radiographic analysis of a low-modulus titanium-alloy femoral total hip component (Two- to six-year follow-up) . J Bone Joint Surg Am . 1985;67:48–56
- Osteolysis after Charnley primary low-friction arthroplasty (A comparison of two matched paired groups) . J Bone Joint Surg Br . 1998;80:585–590
- Primary total hip reconstruction with a titanium fiber-coated prosthesis inserted without cement . J Bone Joint Surg Am . 1993;75:554–571
-
Primary cementless acetabular reconstruction in patients younger than 50 years old
(7 to 11-year results)
.
Clin Orthop Relat Res
. 1997;344:216–226
- . Uncemented total hip arthroplasty in patients 50 years of age or younger . J Arthroplasty . 1997;12:853–862
- Cementless acetabular replacement in the young (A 5 to 10-year prospective study) . Clin Orthop Relat Res . 2000;376:149–155
- Osteolysis in association with a total hip arthroplasty with ceramic bearing surfaces . J Bone Joint Surg Am . 1998;80:1459–1468
- Isolated fracture of the ceramic head after third-generation alumina-on-alumina total hip arthroplasty . J Bone Joint Surg Am . 2008;90:329–336
- Ceramic failure after total hip arthroplasty with an alumina-on-alumina bearing . J Bone Joint Surg Am . 2006;88:780–787
- Ceramic-on-ceramic total hip arthroplasty: Update . J Arthroplasty . 2008;23(7 suppl):39–43
- The squeaking hip: A phenomenon of ceramic-on-ceramic total hip arthroplasty . J Bone Joint Surg Am . 2009;91:1344–1349
- Incidence of “squeaking” after ceramic-on-ceramic total hip arthroplasty . Clin Orthop Relat Res . 2010;468:413–417
- Ceramic-on-ceramic total hip arthroplasty: Incidence of instability and noise . Clin Orthop Relat Res . 2011;469:437–442
- High incidence of squeaking in THAs with alumina ceramic-on-ceramic bearings . Clin Orthop Relat Res . 2008;466:1438–1443
- The effect of stem design on the prevalence of squeaking following ceramic-on-ceramic bearing total hip arthroplasty . J Bone Joint Surg Am . 2010;92:550–557
- The role of patient factors and implant position in squeaking of ceramic-on-ceramic total hip replacements . J Bone Joint Surg Br . 2011;93:439–442
- Squeaking in ceramic-on-ceramic hips: The importance of acetabular component orientation . J Arthroplasty . 2007;22:496–503
J.P.G receives royalties from Smith and Nephew; consultant from CeramTec, DePuy, Smith and Nephew. G.C.L receives institutional support from Zimmer, Smith and Nephew; consulting fees from Covidien and DePuy (less than 1000); speaker/teaching: from Salient Surgical (one time agreement).
PII: S1045-4527(11)00112-X
doi: 10.1053/j.sart.2011.09.003
© 2011 Elsevier Inc. All rights reserved.
« Previous
Next »
Seminars in Arthroplasty
Volume 22, Issue 4
, Pages 229-233
, December 2011
