Seminars in Arthroplasty
Volume 22, Issue 4 , Pages 218-224, December 2011

Ceramic Versus Metal Femoral Heads in Combination With Polyethylene Cups:

Long-Term Wear Analysis at 20 Years

Vitos Orthopädische Klinik Kassel gGmbH, Kassel, Germany

Bearing surfaces are an important implant-related factor in the process of wear and resulting osteolysis. Especially, polyethylene (PE) wear is known to be a major reason for aseptic loosening of the acetabular and femoral components in total hip replacement (THR). In the past, several studies showed the advantages of ceramic femoral ball heads compared with metal ball heads with respect to the resulting PE wear. In this framework, we posed the question whether ceramic and metal ball heads still resulted in similar clinical outcome regarding PE wear after 20-year follow-up. Additionally, we investigated whether wear and osteolysis were correlated within these groups and compared our findings with results from appropriate publications. In this prospective study, 93 nonselected, consecutive uncemented hip arthroplasties were performed in 80 patients with use of the titanium-coated Robert Mathys (RM) cup and the cementless Spotorno stem. Eighty ceramic and 13 metal femoral heads with a diameter of 32 mm were used. The mean age of the patients was 52 years. The average follow-up was 19.3 years. No patient was lost for follow-up. The metal group showed a mean wear rate of 0.190 mm/year, whereas the ceramic group had 0.107 mm/year (P = 0.025). The rate of revision cases was clearly higher within the CoCrMo group showing 6 revisions in 13 cases (46.2%) compared with 11 in 80 cases (13.8%) within the ceramic group. Wear rates were positively correlated to femoral head material (P = 0.025), stem osteolysis (P = 0.003), cup osteolysis (P = 0.011), cup revision (P = 0.041), and cup inclination (P = 0.012). This long-term study shows that during a period of 20 years, ceramic ball heads generate less linear PE wear compared with metal ball heads, thus causing significantly less osteolysis and revisions of either component.

Keywords:  cementless hip arthroplasty , polyethylene wear , ceramic femoral head , monobloc acetabular cup , long term survival

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 10.00 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S1045-4527(11)00110-6

doi:10.1053/j.sart.2011.09.001

Seminars in Arthroplasty
Volume 22, Issue 4 , Pages 218-224, December 2011