Seminars in Arthroplasty
Volume 21, Issue 1 , Pages 27-32 , March 2010

Ceramic-on-Ceramic: For the Hard of Hearing and Living Alone—Opposes

  • Eric Yeung, FRCS
  • ,
  • Paul Thornton-Bott, FRCS
  • ,
  • William L. Walter, MBBS, FRACS, PhD

      Affiliations

    • Corresponding Author InformationAddress reprint requests to William L. Walter, MBBS, FRACS, PhD (Specialist Orthopaedic Group), Mater Clinic, Suite 1.08, Level 1, 3-9 Gillies St, North Sydney, NSW 2060, Australia

References 

  1. Boutin P. [Total arthroplasty of the hip by fritted aluminum prosthesis. Experimental study and 1st clinical applications]. Rev Chir Orthop Reparatrice Appar Mot. 1972;58:229–246
  2. Mahoney OM, Dimon JH. Unsatisfactory results with a ceramic total hip prosthesis. J Bone Joint Surg Am. 1990;72:663–671
  3. Nizard RS, Sedel L, Christel P, et al. Ten-year survivorship of cemented ceramic-ceramic total hip prosthesis. Clin Orthop. 1992;282:53–63
  4. D'Antonio JA, Sutton K. Ceramic materials as bearing surfaces for total hip arthroplasty. J Am Acad Orthop Surg. 2009;17:63–68
  5. Baek S-H, Kim S-Y. Cementless total hip arthroplasty with alumina bearings in patients younger than fifty with femoral head osteonecrosis. J Bone Joint Surg Am. 2008;90:1314–1320
  6. Garcia-Cimbrelo E, Garcia-Rey E, Murcia-Mazón A, et al. Alumina-on-alumina in THA. Clin Orthop. 2008;466:309–316
  7. Ha Y-C, Koo K-H, Jeong S-T, et al. Cementless alumina-on-alumina total hip arthroplasty in patients younger than 50 years: A 5-year minimum follow-up study. J Arthroplasty. 2007;22:184–188
  8. Lusty PJ, Tai CC, Sew-Hoy RP, et al. Third-generation alumina-on-alumina ceramic bearings in cementless total hip arthroplasty. J Bone Joint Surg Am. 2007;89:2676–2683
  9. Yoo JJ, Kim Y-M, Yoon KS, et al. Alumina-on-alumina total hip arthroplasty (A Five-Year minimum follow-up study). J Bone Joint Surg Am. 2005;87:530–535
  10. Murphy SB, Ecker TM, Tannast M. Two-to 9-year clinical results of alumina ceramic-on-ceramic THA. Clin Orthop. 2006;453:97–102
  11. Dumbleton JH, Manley MT, Edidin AA. A literature review of the association between wear rate and osteolysis in total hip arthroplasty. J Arthroplasty. 2002;17:649–661
  12. Jacobs CA, Christensen CP, Greenwald AS, et al. Clinical performance of highly cross-linked polyethylenes in total hip arthroplasty. J Bone Joint Surg Am. 2007;89:2779–2786
  13. Lusty PJ, Watson A, Tuke MA, et al. Wear and acetabular component orientation in third generation alumina-on-alumina ceramic bearings: An analysis of 33 retrievals. [corrected] J Bone Joint Surg Br. 2007;89:1158–1164
  14. Barrack RL, Folgueras A, Munn B, et al. Pelvic lysis and polyethylene wear at 5-8 years in an uncemented total hip. Clin Orthop. 1997;335:211–217
  15. Maloney WJ, Galante JO, Anderson M, et al. Fixation, polyethylene wear, and pelvic osteolysis in primary total hip replacement. Clin Orthop. 1999;369:157–164
  16. Bradford L, Kurland R, Sankaran M, et al. Early failure due to osteolysis associated with contemporary highly cross-linked ultra-high molecular weight polyethylene (A case report). J Bone Joint Surg Am. 2004;86-A:1051–1056
  17. Murali R, Bonar SF, Kirsh G, et al. Osteolysis in third-generation alumina ceramic-on-ceramic hip bearings with severe impingement and titanium metallosis. J Arthroplasty. 2008;23:1240.e13–1240.e19
  18. Barrack RL, Burak C, Skinner HB. Concerns about ceramics in THA. Clin Orthop. 2004;429:73–79
  19. Allain J, Goutallier D, Voisin MC, et al. Failure of a stainless-steel femoral head of a revision total hip arthroplasty performed after a fracture of a ceramic femoral head (A case report). J Bone Joint Surg Am. 1998;80:1355–1360
  20. Allain J, Roudot-Thoraval F, Delecrin J, et al. Revision total hip arthroplasty performed after fracture of a ceramic femoral head: A multicenter survivorship study. J Bone Joint Surg Am. 2003;85:825–830
  21. Skinner HB. Ceramic bearing surfaces. Clin Orthop. 1999;369:83–91
  22. D'Antonio JA, Capello WN, Manley MT, et al. A titanium-encased alumina ceramic bearing for total hip arthroplasty: 3 to 5-year results. Clin Orthop. 2005;441:151–158
  23. D'Antonio J, Capello W, Manley M, et al. Alumina ceramic bearings for total hip arthroplasty: Five-year results of a prospective randomized study. Clin Orthop. 2005;436:164–171
  24. Glaser D, Komistek RD, Cates HE, et al. Clicking and squeaking: In vivo correlation of Sound and separation for different bearing surfaces. J Bone Joint Surg Am. 2008;90(suppl 4):112–120
  25. Jarrett CA, Ranawat AS, Bruzzone M, et al. The squeaking hip: A phenomenon of ceramic-on-ceramic total hip arthroplasty. J Bone Joint Surg Am. 2009;91:1344–1349
  26. Charnley J. Low Friction Arthroplasty of the Hip: Theory and Practice. In: Berlin; New York: Springer-Verlag; 1979;xii, 376 p
  27. Capello WN, D'Antonio JA, Feinberg JR, et al. Ceramic-on-ceramic total hip arthroplasty: Update. J Arthroplasty. 2008;23(7 suppl 1):39–43
  28. Keurentjes JC, Kuipers RM, Wever DJ, et al. High incidence of squeaking in THAs with alumina ceramic-on-ceramic bearings. Clin Orthop. 2008;466:1438–1443
  29. Ranawat AS, Ranawat CS. The squeaking hip: A cause for concern-agrees. Orthopedics. 2007;30:738–743
  30. Restrepo C, Parvizi J, Kurtz SM, et al. The noisy ceramic hip: Is component malpositioning the cause?. J Arthroplasty. 2008;23:643–649
  31. Rodriguez JA, Gonzalez DelaValle A, McCook N. Squeaking in total hip replacement: A cause for concern. Orthopedics. 2008;31:877–878
  32. Walter WL, O'Toole GC, Walter WK, et al. Squeaking in ceramic-on-ceramic hips: The importance of acetabular component orientation. J Arthroplasty. 2007;22:496–503
  33. Walter WL, Waters TS, Gillies M, et al. Squeaking hips. J Bone Joint Surg Am. 2008;90(suppl 4):102–111
  34. Yang CC, Kim RH, Dennis DA. The squeaking hip: A cause for concern-disagrees. Orthopedics. 2007;30:739–742
  35. Back DL, Dalziel R, Young D, et al. Early results of primary Birmingham hip resurfacings (An independent prospective study of the first 230 hips). J Bone Joint Surg Br. 2005;87:324–329
  36. Ebied A, Journeaux S. (iv) Metal-on-metal hip resurfacing. Curr Orthop. 2002;16:420–425
  37. Hing CB, Back DL, Bailey M, et al. The results of primary Birmingham hip resurfacings at a mean of five years (An independent prospective review of the first 230 hips). J Bone Joint Surg Br. 2007;89:1431–1438
  38. Moore KD, Beck PR, Petersen DW, et al. Early failure of a Cross-linked polyethylene acetabular liner (A Case Report). J Bone Joint Surg Am. 2008;90:2499–2504
  39. Taylor S, Manley MT, Sutton K. The role of stripe wear in causing acoustic emissions from alumina ceramic-on-ceramic bearings. J Arthroplasty. 2007;22(7 suppl 1):47–51
  40. Walter WL: Retrival analysis of squeaking alumina ceramic on ceramic bearings. J Arthroplasty (in press)
  41. Walter WL, Insley GM, Walter WK, et al. Edge loading in third generation alumina ceramic-on-ceramic bearings: Stripe wear. J Arthroplasty. 2004;19:402–413
  42. Hozack W, Parvizi J, Bender: The surgical treatment of hip arthritis, in Lusty PJ, Walter WL, and Young D (eds): Posterior and Posteroinferior Approaches (chapter 14).
  43. Morlock M, Nassutt R, Janssen R, et al. Mismatched wear couple zirconium oxide and aluminum oxide in total hip arthroplasty. J Arthroplasty. 2001;16:1071–1074
  44. Restrepo C, Post Z, Kai B, et al: The effect of stem design on the incidence of squeaking in ceramic on ceramic bearing total hip arthroplasty. J Arthroplasty (in press)
  45. Chevillotte C, Trousdale RT, Chen Q, et al. The 2009 Frank Stinchfield Award: “Hip squeaking”: A biomechanical study of ceramic-on-ceramic bearing surfaces. Clin Orthop. 2010;468:345–350
  46. Toni A, Traina F, Stea S, et al. Early diagnosis of ceramic liner fracture (Guidelines based on a twelve-year clinical experience). J Bone Joint Surg Am. 2006;88(suppl 4):55–63

 Our institute receives research funding from Depuy (Johnson & Johnson) and Stryker.

PII: S1045-4527(10)00006-4

doi: 10.1053/j.sart.2010.01.005

Seminars in Arthroplasty
Volume 21, Issue 1 , Pages 27-32 , March 2010