Seminars in Arthroplasty
Volume 17, Issue 3 , Pages 125-133 , September 2006

Alumina-on-Alumina Articulation in Total Hip Arthroplasty: From Bench-side to Bedside

  • Moussa Hamadouche, MD, PhD

      Affiliations

    • Laboratoire de Recherches Orthopédiques (UMR CNRS 7052), Paris, France.
    • Department of Orthopaedic Surgery and Traumatoly, Hôpital Lariboisière (University Paris 7), Paris, France.
    • Corresponding Author InformationAddress reprint requests to Moussa Hamadouche, MD, PhD, Department of Orthopaedic and Reconstructive Surgery, Service A, Centre Hospitalo–Universitaire Cochin–Port Royal, 27 Rue du Faubourg St Jacques, 75014, Paris, France.
  • ,
  • Alain Meunier, PhD

      Affiliations

    • Laboratoire de Recherches Orthopédiques (UMR CNRS 7052), Paris, France.
  • ,
  • Rémy Nizard, MD

      Affiliations

    • Department of Orthopaedic and Reconstructive Surgery (Service A), Centre Hospitalo-Universitaire Cochin- Port Royal (University Paris 5), Paris, France.
  • ,
  • Didier Hannouche, MD

      Affiliations

    • Department of Orthopaedic and Reconstructive Surgery (Service A), Centre Hospitalo-Universitaire Cochin- Port Royal (University Paris 5), Paris, France.
  • ,
  • Pascal Bizot, MD

      Affiliations

    • Department of Orthopaedic Surgery and Traumatoly, Hôpital Lariboisière (University Paris 7), Paris, France.
  • ,
  • Laurent Sedel, MD

      Affiliations

    • Laboratoire de Recherches Orthopédiques (UMR CNRS 7052), Paris, France.
    • Department of Orthopaedic and Reconstructive Surgery (Service A), Centre Hospitalo-Universitaire Cochin- Port Royal (University Paris 5), Paris, France.

References 

  1. Willert HG. Reactions of the articular capsule to wear products of artificial joint prostheses. J Biomed Mater Res. 1977;11:157–164
  2. Goldring SR, Clark CR, Wright TM. The problem in total joint arthroplasty: aseptic loosening. J Bone Joint Surg. 1993;75A:799–801
  3. Goodman SB, Huie P, Song Y, et al. Loosening and osteolysis of cemented joint arthroplasties: a biologic spectrum. Clin Orthop. 1997;337:149–163
  4. Boutin P. Arthroplastie totale de la hanche par prothèse en alumine frit,e: etude exp,rimentale et premères applications cliniques. Rev Chir Orthop Reparatrice Appar Mot. 1972;58:229–246
  5. Hamadouche M, Sedel L. Ceramics in orthopaedics. J Bone Joint Surg. 2000;82B:1095–1099
  6. Nevelos JE, Ingham E, Doyle C, et al. Wear of HIPed and non-HIPed alumina-alumina hip joints under standard and severe simulator testing conditions. Biomaterials. 2001;22:2191–2197
  7. Christel P. Biocompatibility of surgical-grade dense polycristalline alumina. Clin Orthop. 1992;282:10–18
  8. Dorlot JM. Long-term effects of alumina components in total hip prostheses. Clin Orthop. 1992;282:47–52
  9. Walter A. On the material and the tribology of alumina-alumina couplings for hip joint prostheses. Clin Orthop. 1992;282:31–46
  10. Clarke IC, Willmann G. Structural ceramics in orthopedics. In:  Cameron HU editors. Bone Implant Interface. St Louis: Mosby; 1994;p. 203–252
  11. Cooper J, Dowson D, Fisher J, et al. Ceramic bearing surfaces in total artificial joints: resistance to third body wear damage from bone cement particles. J Med Eng. 1991;15:63
  12. Davidson JA, Poggie RA, Mishra AK. Abrasive wear of ceramic, metal and UHMWPE bearing surfaces from third-body bone, PMMA bone cement, and titanium debris. Biomed Mater Eng. 1994;4:213–229
  13. Sedel L. The tribology of hip replacement. In:  Kenwright J,  Dupar J, Fulford  editor. European Instructional Course Lectures. Vol 3:London: The British Editorial Society of Bone and Joint Surgery; 1997;p. 25–33
  14. Fritsch EW, Gleitz M. Ceramic femoral head fractures in total hip arthroplasty. Clin Orthop. 1996;328:129–136
  15. Sedel L, Kerboull L, Christel P, et al. Alumina-on-alumina hip replacement (results and survivorship in young patients). J Bone Joint Surg. 1990;72B:658–663
  16. Sedel L, Nizard R, Kerboull L, et al. Alumina–alumina hip replacement in patients younger than 50 years old. Clin Orthop. 1994;298:175–183
  17. Willmann G. Ceramics for total hip replacement: what a surgeon should know. Orthopedics. 1998;21:173–177
  18. Heck DA, Partridge CM, Reuben JD, et al. Prosthetic component failures in hip arthroplasty surgery. J Arthroplasty. 1995;10:575–580
  19. Dörre E, Dawihl W, Krohn U, et al. Do ceramic components of hip joints maintain their strength in human bodies. In:  Vincenzini P editors. Ceramics in Surgery. Amsterdam: Elsevier; 1983;p. 61–72
  20. Osterholm HH, Day DE. Dense alumina aged in vivo. J Biomed Mater Res. 1981;15:279–288
  21. Boutin P, Christel P, Dorlot JM, et al. The use of dense alumina–alumina ceramic combination in total hip replacement. J Biomed Mater Res. 1988;22:1203–1232
  22. Breval E, Breznak J, MacMillian NH. Sliding friction and wear of structural ceramics. J Mater Sci. 1986;21:931–935
  23. Clarke IC, Dorlot JM, Graham J, et al. Biomechanical stability and design: wear. Ann N Y Acad Sci. 1988;523:292–296
  24. Clarke IC, Good V, Williams P, et al. Ultra-low wear rates for rigid-on-rigid bearings in total hip replacements. Proc Inst Mech Eng. 2000;214:331–347
  25. Dorlot JM, Christel P, Meunier A. Wear analysis of retrieved alumina heads and sockets of hip prostheses. J Biomed Mater Res. 1989;23(suppl A3):299–310
  26. McKellop H, Clarke IC, Markolf KL, et al. Friction and wear properties of polymer, metal and ceramic prosthetic joint materials evaluated on a multichannel screening device. J Biomed Mater Res. 1981;5:619–653
  27. Refior HJ, Plitz W, Walter A. Ex vivo and in vitro analysis of the alumina alumina bearing system for hip joint prostheses. In:  Sedel L,  Rey C editor. Bioceramics. Vol 10:Oxford, UK: Elsevier Science, Ltd; 1997;p. 127–130
  28. Walker PS, Bullough PG. The effects of friction and wear in artificial joints. Orthop Clin North Am. 1973;4:275–293
  29. Walter A, Plitz W. Wear mechanisms of alumina–ceramic bearing surfaces of hip joint prostheses. In:  Ducheyne P,  Van de Perre G,  Aubert A editor. Biomaterials and Biomechanics. Amsterdam: Elsevier Science; 1984;p. 55–60
  30. Phipatanakul WP, Johnson SA, Good V, et al. The fallacy of evaluating biomaterials wear-rates with water as a lubricant: a hip simulator study of alumina-PTFE and Co-Cr-PTFE combination. J Biomed Mater Res. 1998;39:229–233
  31. Oonishi H, Nishida M, Kawanabe K, et al. In-vitro wear of Al2O3/Al2O3 implant combination with over 10 million cycles. 1999;Proceedings of the 45th Annual Meeting of the Orthopaedic Research Society, Los Angeles, CA
  32. Hatton A, Nevelos JE, Nevelos AB, et al. Alumina–alumina artificial hip joints: Part I. A histological analysis and characterisation of wear debris by laser capture microdissection of tissues retrieved at revision. Biomaterials. 2002;23:3429–3440
  33. Nevelos JE, Ingham E, Doyle C, et al. Microseparation of the centers of alumina–alumina artificial hip joints during simulator testing produces clinically relevant wear rates and patterns. J Arthroplasty. 2000;15:793–795
  34. Tipper JL, Hatton A, Nevelos JE, et al. Alumina–alumina artificial hip joints: Part II. Characterisation of the wear debris from in vitro hip joint simulations. Biomaterials. 2002;23:3341–3348
  35. Wallbridge N, Dowson D. The walking activity of patients with artificial hip joints. Eng Med. 1982;11:95–96
  36. Komistek R, Northcut E, Bizot P, et al. In vivo determination of hip joint separation in subjects having either an alumina-on-alumina or alumina-on-polyethylene total hip arthroplasty. 2002;Proceedings of the 69th Annual Meeting of the American Academy of Orthopaedic Surgeons, Dallas, TX
  37. Fruh HJ, Willmann G, Pfaff HG. Wear characteristics of ceramic-on-ceramic for hip endoprostheses. Biomaterials. 1997;18:873–876
  38. Hulbert SF. The use of alumina and zirconia in surgical implants. In:  Hench HH,  Wilson J editor. An Introduction to Bioceramics. Singapore: River Edge, NJ, World Scientific; 1993;p. 25–40
  39. Isaac GH, Wroblewski BM, Atkinson JR, et al. A tribological study of retrieved hip prostheses. Clin Orthop. 1992;276:115–125
  40. Nevelos JE, Prudhommeaux F, Hamadouche M, et al. Comparative analysis of two different types of alumina–alumina hip prosthesis retrieved for aseptic loosening. J Bone Joint Surg. 2001;83B:598–603
  41. Plitz W, Griss P. Clinical, histo-morpholigical and material related observations on removed alumina–ceramic hip joint components. In:  Weinstein A,  Gibbons D,  Brown S, et al. editor. Implant Retrieval: Material and Histological Analysis. Washington DC: National Bureau of Standards Spec Pub 601, US Department of Commerce; 1981;p. 131–156
  42. Plitz W, Hoss HU. Wear of alumina-ceramic hip-joints: some clinical and tribological aspects. In:  Winter G,  Gibbons D,  Plenk H editor. Biomaterials 1980 (Advances in Biomaterials). Vol 3:New York: John Wiley & Sons; 1982;p. 187–196
  43. Walter A, Plitz W. Wear of retreived alumina-ceramic hip-joint prostheses. In:  Vincenzini P editors. Ceramics in Surgery. Amsterdam: Elsevier Science; 1983;p. 253–259
  44. Prudhommeaux F, Hamadouche M, Nevelos J, et al. Wear of alumina-on-alumina total hip arthroplasties at a mean 11-year followup. Clin Orthop. 2000;379:113–122
  45. Boutin P, Blanquaert D. Le frottement alumine–alumine en chirurgie de la hanche: 1205 arthroplasties totales. Rev Chir Orthop. 1981;67:279–287
  46. Mittelmeier H, Heisel J. Sixteen-years’ experience with ceramic hip prostheses. Clin Orthop. 1992;282:64–72
  47. Heimke G, Griss P. Five years experience with ceramic-metal-composite hip endoprostheses: II. Mechanical evaluations and improvements. Arch Orthop Trauma Surg. 1981;98:165–171
  48. Wu C, Rice RW, Johnson D, et al. Grain size dependence of wear in ceramics. Ceram Eng Sci Proc. 1985;6:995–1011
  49. Griss P, von Andrian-Werburg HV, Krempien B, et al. Biological activity and histocompatibility of dense Al2O3-MgO ceramic implants in rats. J Biomed Mater Res. 1973;7:453–462
  50. Leray J, Christel P. Tissue tolearnce of wear debris from arthroplasties. In:  Winter G,  Gibbons D,  Plenk H editor. Biomaterials 1980 (Advances in Biomaterials). Vol 3:New York: John Wiley & Sons; 1982;p. 197–206
  51. Savio JA, Overcamp LM, Black J. Size and shape of biomaterial wear debris. Clin Mater. 1994;15:101–147
  52. Bohler M, Mochida Y, Bauer T, et al. Wear debris from two different alumina on aluminatotal hip arthroplasties. J Bone Joint Surg. 2000;82B:901–909
  53. Harms J, Mausle E. Tissue reaction to ceramic implant material. J Biomed Mater Res. 1979;13:67–87
  54. Pizzoferrato A, Stea S, Sudanese A, et al. Morphometric and microanalytical analyses of alumina wear particles in hip prostheses. Biomaterials. 1993;14:583–587
  55. Lerouge S, Huk O, Yahia L, et al. Characterization of in vivo wear debris from ceramic–ceramic total hip arthroplasties. J Biomed Mater Res. 1996;32:627–633
  56. Lerouge S, Huk O, Yahia L, et al. Ceramic–ceramic and metal–polyethylene total hip replacements: comparison of pseudomembranes after loosening. J Bone Joint Surg. 1997;79B:135–139
  57. O’Leary JF, Mallory TH, Kraus TJ, et al. Mittelmeier ceramic total hip arthroplasty: a retrospective study. J Arthroplasty. 1988;3:87–96
  58. Yoon TR, Rowe SM, Jung ST, et al. Osteolysis in association with a total hip arthroplasty with ceramic bearing surfaces. J Bone Joint Surg. 1998;80A:1459–1468
  59. Sedel L, Simeon J, Meunier A, et al. Prostaglandin E2 level in tissue surrounding aseptic failed total hips: effects of materials. Arch Orthop Trauma Surg. 1992;111:255–258
  60. Liagre B, Moalic S, Vergne P, et al. Effects of alumina and zirconium dioxide particles on arachidonic acid metabolism and proinflammatory interleukin production in osteoarthritis and rheumatoid synovial cells. J Bone Joint Surg. 2002;84B:920–930
  61. Catelas I, Huk OL, Petit A, et al. Flow cytometric analysis of macrophage response to ceramic and polyethylene particles: effects of size, concentration, and composition. J Biomed Mater Res. 1998;41:600–607
  62. Catelas I, Petit A, Marchand R, et al. Cytotoxicity and macrophage cytokine release induced by ceramic and polyethylene particles in vitro. J Bone Joint Surg. 1999;81B:516–521
  63. Petit A, Catelas I, Antoniou J, et al. Differential apoptotic response of J774 macrophages to alumina and ultra-high-molecular-weight polyethylene particles. J Orthop Res. 2002;20:9–15
  64. Nizard RS, Sedel L, Christel P, et al. Ten-year survivorship of cemented ceramic-ceramic total hip prosthesis. Clin Orthop. 1992;282:53–63
  65. Hamadouche M, Nizard R, Meunier A, et al. Cementless bulk alumina socket: preliminary results at 6 years. J Arthroplasty. 1999;14:701–707
  66. Witvoet J, Darman Z, Christel P, et al. Arthroplastie totale de hanche avec anneau cotyloidien en titane viss,: devenir de 446 prothèses avec un recul moyen de 4 ans. Rev Chir Orthop. 1993;79:542–552
  67. Bizot P, Larrouy M, Witvoet J, et al. Press-fit metal-backed alumina sockets: a minimum 5-year followup study. Clin Orthop. 2000;379:134–142
  68. Bizot P, Nizard R, Hamadouche M, et al. Prevention of wear and osteolysis: alumina-on-alumina bearing. Clin Orthop. 2001;393:85–93
  69. Hamadouche M, Meunier A, Greenspan D, et al. Bioactivity of sol-gel bioactive glass coated alumina implants. J Biomed Mater Res. 2000;52:422–429
  70. Hamadouche M, Boutin P, Daussange J, et al. Alumina-on-alumina total hip arthroplasty: a minimum 18.5-year follow-up study. J Bone Joint Surg. 2002;84A:69–77
  71. Bizot P, Hannouche D, Nizard R, et al. Hybrid alumina total hip arthroplasty using a press-fit metal-backed sockets in patients younger than 55 years: a six- to 11-year evaluation. J Bone Joint Surg. 2004;86B:190–194
  72. Hannouche D, Nich C, Bizot P, et al. Fractures of ceramic bearings: history and present status. Clin Orthop. 2003;417:19–26
  73. Griss P, Heimke G. Five years experience with ceramic-metal-composite hip endoprostheses: I. Clinical evaluation. Arch Orthop Trauma Surg. 1981;98:157–164
  74. Boehler M, Knahr K, Plenk HJ, et al. Long-term results of uncemented alumina acetabular implants. J Bone Joint Surg. 1994;76B:53–59
  75. Garcia-Cimbrelo E, Sayanes J, Minuesa A, et al. Ceramic–ceramic prosthesis after 10 years. J Arthroplasty. 1996;11:773–781
  76. Toni A, Terzi S, Sudanese A, et al. The use of ceramic in prosthetic hip surgery: the state of the art. Chir Organ Mov. 1995;80:125–137
  77. Huo M, Martin R, Zatorski L, Keggi K. Total hip replacements using the ceramic Mittelmeier prosthesis. Clin Orthop. 1996;332:143–150
  78. Wirganowicz PZ, Thomas BJ. Massive osteolysis after ceramic on ceramic total hip arthroplasty: a case report. Clin Orthop. 1997;338:100–104
  79. Meunier A, Nizard R, Bizot P. Clinical results of ceramic bearings in Europe, in ASTM STP 1346. In:  Jacobs JJ,  Craig TL editor. Symposium on Alternative Bearing Surfaces in Total Joint Replacement. San Diego, CA: American Society for Testing and Materials; 1998;

PII: S1045-4527(06)00055-1

doi: 10.1053/j.sart.2006.09.006

Seminars in Arthroplasty
Volume 17, Issue 3 , Pages 125-133 , September 2006