- . Reactions of the articular capsule to wear products of artificial joint prostheses. J Biomed Mater Res. 1977;11:157–164
- . The problem in total joint arthroplasty: aseptic loosening. J Bone Joint Surg. 1993;75A:799–801
- Loosening and osteolysis of cemented joint arthroplasties: a biologic spectrum. Clin Orthop. 1997;337:149–163
- . Arthroplastie totale de la hanche par prothèse en alumine frit,e: etude exp,rimentale et premères applications cliniques. Rev Chir Orthop Reparatrice Appar Mot. 1972;58:229–246
- . Ceramics in orthopaedics. J Bone Joint Surg. 2000;82B:1095–1099
- Wear of HIPed and non-HIPed alumina-alumina hip joints under standard and severe simulator testing conditions. Biomaterials. 2001;22:2191–2197
- . Biocompatibility of surgical-grade dense polycristalline alumina. Clin Orthop. 1992;282:10–18
- . Long-term effects of alumina components in total hip prostheses. Clin Orthop. 1992;282:47–52
- . On the material and the tribology of alumina-alumina couplings for hip joint prostheses. Clin Orthop. 1992;282:31–46
- . Structural ceramics in orthopedics. In: Cameron HU editors. Bone Implant Interface. St Louis: Mosby; 1994;p. 203–252
- Ceramic bearing surfaces in total artificial joints: resistance to third body wear damage from bone cement particles. J Med Eng. 1991;15:63
- . Abrasive wear of ceramic, metal and UHMWPE bearing surfaces from third-body bone, PMMA bone cement, and titanium debris. Biomed Mater Eng. 1994;4:213–229
- . The tribology of hip replacement. In: Kenwright J, Dupar J, Fulford editor. European Instructional Course Lectures. Vol 3:London: The British Editorial Society of Bone and Joint Surgery; 1997;p. 25–33
- . Ceramic femoral head fractures in total hip arthroplasty. Clin Orthop. 1996;328:129–136
- Alumina-on-alumina hip replacement (results and survivorship in young patients). J Bone Joint Surg. 1990;72B:658–663
- Alumina–alumina hip replacement in patients younger than 50 years old. Clin Orthop. 1994;298:175–183
- . Ceramics for total hip replacement: what a surgeon should know. Orthopedics. 1998;21:173–177
- Prosthetic component failures in hip arthroplasty surgery. J Arthroplasty. 1995;10:575–580
- Do ceramic components of hip joints maintain their strength in human bodies. In: Vincenzini P editors. Ceramics in Surgery. Amsterdam: Elsevier; 1983;p. 61–72
- . Dense alumina aged in vivo. J Biomed Mater Res. 1981;15:279–288
- The use of dense alumina–alumina ceramic combination in total hip replacement. J Biomed Mater Res. 1988;22:1203–1232
- . Sliding friction and wear of structural ceramics. J Mater Sci. 1986;21:931–935
- Biomechanical stability and design: wear. Ann N Y Acad Sci. 1988;523:292–296
- Ultra-low wear rates for rigid-on-rigid bearings in total hip replacements. Proc Inst Mech Eng. 2000;214:331–347
- . Wear analysis of retrieved alumina heads and sockets of hip prostheses. J Biomed Mater Res. 1989;23(suppl A3):299–310
- Friction and wear properties of polymer, metal and ceramic prosthetic joint materials evaluated on a multichannel screening device. J Biomed Mater Res. 1981;5:619–653
- . Ex vivo and in vitro analysis of the alumina alumina bearing system for hip joint prostheses. In: Sedel L, Rey C editor. Bioceramics. Vol 10:Oxford, UK: Elsevier Science, Ltd; 1997;p. 127–130
- . The effects of friction and wear in artificial joints. Orthop Clin North Am. 1973;4:275–293
- . Wear mechanisms of alumina–ceramic bearing surfaces of hip joint prostheses. In: Ducheyne P, Van de Perre G, Aubert A editor. Biomaterials and Biomechanics. Amsterdam: Elsevier Science; 1984;p. 55–60
- The fallacy of evaluating biomaterials wear-rates with water as a lubricant: a hip simulator study of alumina-PTFE and Co-Cr-PTFE combination. J Biomed Mater Res. 1998;39:229–233
- In-vitro wear of Al2O3/Al2O3 implant combination with over 10 million cycles. 1999;Proceedings of the 45th Annual Meeting of the Orthopaedic Research Society, Los Angeles, CA
- Alumina–alumina artificial hip joints: Part I. A histological analysis and characterisation of wear debris by laser capture microdissection of tissues retrieved at revision. Biomaterials. 2002;23:3429–3440
- Microseparation of the centers of alumina–alumina artificial hip joints during simulator testing produces clinically relevant wear rates and patterns. J Arthroplasty. 2000;15:793–795
- Alumina–alumina artificial hip joints: Part II. Characterisation of the wear debris from in vitro hip joint simulations. Biomaterials. 2002;23:3341–3348
- . The walking activity of patients with artificial hip joints. Eng Med. 1982;11:95–96
- In vivo determination of hip joint separation in subjects having either an alumina-on-alumina or alumina-on-polyethylene total hip arthroplasty. 2002;Proceedings of the 69th Annual Meeting of the American Academy of Orthopaedic Surgeons, Dallas, TX
- . Wear characteristics of ceramic-on-ceramic for hip endoprostheses. Biomaterials. 1997;18:873–876
- . The use of alumina and zirconia in surgical implants. In: Hench HH, Wilson J editor. An Introduction to Bioceramics. Singapore: River Edge, NJ, World Scientific; 1993;p. 25–40
- A tribological study of retrieved hip prostheses. Clin Orthop. 1992;276:115–125
- Comparative analysis of two different types of alumina–alumina hip prosthesis retrieved for aseptic loosening. J Bone Joint Surg. 2001;83B:598–603
- . Clinical, histo-morpholigical and material related observations on removed alumina–ceramic hip joint components. In: Weinstein A, Gibbons D, Brown S, et al. editor. Implant Retrieval: Material and Histological Analysis. Washington DC: National Bureau of Standards Spec Pub 601, US Department of Commerce; 1981;p. 131–156
- . Wear of alumina-ceramic hip-joints: some clinical and tribological aspects. In: Winter G, Gibbons D, Plenk H editor. Biomaterials 1980 (Advances in Biomaterials). Vol 3:New York: John Wiley & Sons; 1982;p. 187–196
- . Wear of retreived alumina-ceramic hip-joint prostheses. In: Vincenzini P editors. Ceramics in Surgery. Amsterdam: Elsevier Science; 1983;p. 253–259
- Wear of alumina-on-alumina total hip arthroplasties at a mean 11-year followup. Clin Orthop. 2000;379:113–122
- . Le frottement alumine–alumine en chirurgie de la hanche: 1205 arthroplasties totales. Rev Chir Orthop. 1981;67:279–287
- . Sixteen-years’ experience with ceramic hip prostheses. Clin Orthop. 1992;282:64–72
- . Five years experience with ceramic-metal-composite hip endoprostheses: II. Mechanical evaluations and improvements. Arch Orthop Trauma Surg. 1981;98:165–171
- Grain size dependence of wear in ceramics. Ceram Eng Sci Proc. 1985;6:995–1011
- Biological activity and histocompatibility of dense Al2O3-MgO ceramic implants in rats. J Biomed Mater Res. 1973;7:453–462
- . Tissue tolearnce of wear debris from arthroplasties. In: Winter G, Gibbons D, Plenk H editor. Biomaterials 1980 (Advances in Biomaterials). Vol 3:New York: John Wiley & Sons; 1982;p. 197–206
- . Size and shape of biomaterial wear debris. Clin Mater. 1994;15:101–147
- Wear debris from two different alumina on aluminatotal hip arthroplasties. J Bone Joint Surg. 2000;82B:901–909
- . Tissue reaction to ceramic implant material. J Biomed Mater Res. 1979;13:67–87
- Morphometric and microanalytical analyses of alumina wear particles in hip prostheses. Biomaterials. 1993;14:583–587
- Characterization of in vivo wear debris from ceramic–ceramic total hip arthroplasties. J Biomed Mater Res. 1996;32:627–633
- Ceramic–ceramic and metal–polyethylene total hip replacements: comparison of pseudomembranes after loosening. J Bone Joint Surg. 1997;79B:135–139
- Mittelmeier ceramic total hip arthroplasty: a retrospective study. J Arthroplasty. 1988;3:87–96
- Osteolysis in association with a total hip arthroplasty with ceramic bearing surfaces. J Bone Joint Surg. 1998;80A:1459–1468
- Prostaglandin E2 level in tissue surrounding aseptic failed total hips: effects of materials. Arch Orthop Trauma Surg. 1992;111:255–258
- Effects of alumina and zirconium dioxide particles on arachidonic acid metabolism and proinflammatory interleukin production in osteoarthritis and rheumatoid synovial cells. J Bone Joint Surg. 2002;84B:920–930
- Flow cytometric analysis of macrophage response to ceramic and polyethylene particles: effects of size, concentration, and composition. J Biomed Mater Res. 1998;41:600–607
- Cytotoxicity and macrophage cytokine release induced by ceramic and polyethylene particles in vitro. J Bone Joint Surg. 1999;81B:516–521
- Differential apoptotic response of J774 macrophages to alumina and ultra-high-molecular-weight polyethylene particles. J Orthop Res. 2002;20:9–15
- Ten-year survivorship of cemented ceramic-ceramic total hip prosthesis. Clin Orthop. 1992;282:53–63
- Cementless bulk alumina socket: preliminary results at 6 years. J Arthroplasty. 1999;14:701–707
- Arthroplastie totale de hanche avec anneau cotyloidien en titane viss,: devenir de 446 prothèses avec un recul moyen de 4 ans. Rev Chir Orthop. 1993;79:542–552
- Press-fit metal-backed alumina sockets: a minimum 5-year followup study. Clin Orthop. 2000;379:134–142
- Prevention of wear and osteolysis: alumina-on-alumina bearing. Clin Orthop. 2001;393:85–93
- Bioactivity of sol-gel bioactive glass coated alumina implants. J Biomed Mater Res. 2000;52:422–429
- Alumina-on-alumina total hip arthroplasty: a minimum 18.5-year follow-up study. J Bone Joint Surg. 2002;84A:69–77
- Hybrid alumina total hip arthroplasty using a press-fit metal-backed sockets in patients younger than 55 years: a six- to 11-year evaluation. J Bone Joint Surg. 2004;86B:190–194
- Fractures of ceramic bearings: history and present status. Clin Orthop. 2003;417:19–26
- . Five years experience with ceramic-metal-composite hip endoprostheses: I. Clinical evaluation. Arch Orthop Trauma Surg. 1981;98:157–164
- Long-term results of uncemented alumina acetabular implants. J Bone Joint Surg. 1994;76B:53–59
- Ceramic–ceramic prosthesis after 10 years. J Arthroplasty. 1996;11:773–781
- The use of ceramic in prosthetic hip surgery: the state of the art. Chir Organ Mov. 1995;80:125–137
- . Total hip replacements using the ceramic Mittelmeier prosthesis. Clin Orthop. 1996;332:143–150
- . Massive osteolysis after ceramic on ceramic total hip arthroplasty: a case report. Clin Orthop. 1997;338:100–104
- . Clinical results of ceramic bearings in Europe, in ASTM STP 1346. In: Jacobs JJ, Craig TL editor. Symposium on Alternative Bearing Surfaces in Total Joint Replacement. San Diego, CA: American Society for Testing and Materials; 1998;